As you can see in the attached photo, the cable has sawn through both the cover and mounting end. This happened because of the sharp bend required by the design. Please provide a new cable and instruction on how to prevent the problem from occurring again.
I live in Boston, MA area and bought an ST230P 1/25/2015. Biggest problem I am having is that the auger belt broke after about 10 - 15 hours total operation. (Worked great until belt broke). Searched up and down all local dealers and belt manufactures for replacement with no luck. Closest I could get was a rubber v-belt with same dimension. This belt broke after about 5 minutes operation.
I believe the cause of belt wear on my machine is the belt guide on the idler arm opposite the idler pulley. The guide pulls the belt off the auger drive pulley to tension it when the lever is pressed to engage auger. Unless it was installed wrong?
Anyone else experience similar problems with auger belt??
My used-one-time-for-one-hour ST224 will not start. I've tried all I can figure out to do. Quadruple-checked that I have all the settings correct for starting. New gasoline. At the end of the previous use I ran it dry so it should not be a gummed up carb issue.
I want to try starting fluid but as there is no air filter, there's no place to try spraying it into. So short of calling for expensive (I need it transported) service for a brand new unit, what else can I do?